Technical Info

• Anti-static device • Locking device • Long cycle life • Test standard: API 598 • API 607 4th edition fire safe approval • Vacuum service to 29″ Hg

• ISO 5211 actuator mounting pad • Body: ASTM A351 Gr. CF8M

• Handle in ASTM A536 Gr. 65-45-12 / SS304 • WARNING: do not exceed reasonable temperature and/or electrical load

• Blow-out proof stem design • Adjustable stem packing

• General use: 50 bar / 750 PSI (see chart on reverse) • 19 bar / 275 PSI for ASME 150 CF8M (see chart on reverse) • Steam rating: 10 bar / 150 PSI WSP • -45,5°C to +246°C (-50°F to +475°F) • WARNING: freezing of the fluid in the installation may severely damage the valve

• ME-PTFE seal kits: -replaces PTFE, RPTFE and FPA -low deformation under load -low permeation

• ANSI B16.5, B16.10 and B16.34 full compliance

*ME-PTFE is moleculary enhanced PTFE

Part description Quantity Part Material
Body
1
ASTM A351-CF8M
Cap
1
ASTM A351-CF8M
Ball
1
ASTM A351-CF8M
Stem
1
ASTM A276 Gr. 316
Seat
2
ME-PTFE*
Gasket
1
GRAFOIL
Thrust washer
1
ME-PTFE*
Packing
1
GRAFOIL
Gland
1
ASTM A351- Gr.CF8
Stopper
1
SS304
Torque for actuator sizing in-lb
Torque correction factors

Valve torque can vary according to operating frequency, temperature and friction characteristics of the media. If media has more or less friction than water, multiply torque by the following factors.

Lubricating oils or liquids  0.8
Dry gases, natural gas 1.5
Slurries or liquids bearing abrasive particles 1.5÷2.5

 

Pressure - temperature chart (°F)

Image removed.

Pressure - temperature chart (°C)

Image removed.

WARNING: This product can expose you to chemicals including lead which is known to the state of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov

Technical material

Ask for additional information on the whole range of RuB products and consult with your supplier for special applications.

XCE136
-
4266

To view all available technical material
Register as a client